DC Bias Elimination in Multi-Active-Bridge Converters using Dynamic Feedforward Decoupling

The presence of a DC bias in the ac stage currents of a multi-active-bridge converter (MAB) deteriorates converter efficiency. The DC biases in the MAB cells are dynamically coupled, but existing strategies do not clearly tackle this cross- coupling. This paper proposes a simplified dynamic model of the DC bias in MAB and a dynamic feedforward control scheme to eliminate the same. In order to simplify transient behavior and facilitate control design, an approximated dynamic model, capturing the higher-order dynamics, is proposed. The proposed controller design is outlined for a generic MAB and validated in simulation on a 50V , 200W quad-active-bridge (QAB).

Rights

Use and reproduction:

No license. The provisions of the German Copyright Act (UrhG) apply.

Please note that individual components of the publication may be subject to other licensing or copyright conditions.

Cite

Citation style:
Could not load citation form.